The BMC Hardware Sentry TrueSight Presentation Server API v1.0 connector(https://docs.bmc.com/docs/display/tsps107/Getting+started) OpenAPI specification.
The BMC Hardware Sentry TrueSight Presentation Server API provides the capability to access data from various TrueSight products to provide a consolidated set of views for monitoring the infrastructure, real and synthetic applications, and capacity planning.
Key Features
- Programmatic access to create and manage resources via REST API
- Manage user accounts and profiles
- Secure authentication with API key or OAuth support
Prerequisites
Before using this connector in your Ballerina application, complete the following:
- Create a user account.
- Obtaining tokens
- Obtain your token by following this link.
Clients
bmc.truesightpresentationserver: Client
This is a generated connector for BMC Hardware Sentry TrueSight Presentation Server REST API v1.0 OpenAPI specification.
The BMC Hardware Sentry TrueSight Presentation Server API provides the capability to access data from various TrueSight products to provide a consolidated set of views for monitoring the infrastructure, real and synthetic applications, and capacity planning.
Constructor
Gets invoked to initialize the connector.
The connector initialization requires setting the API credentials.
Create a user account in BMC Hardware Sentry TrueSight Presentation Server and obtain tokens following this guide.
init (ApiKeysConfig apiKeyConfig, string serviceUrl, ConnectionConfig config)- apiKeyConfig ApiKeysConfig - API keys for authorization
- serviceUrl string - URL of the target service
- config ConnectionConfig {} - The configurations to be used when initializing the
connector
collectNow
function collectNow(int deviceId, string monitorClass) returns ActionResponse|errorTriggers a new collect on a specific device.
Parameters
- deviceId int - The ID of the device.
- monitorClass string - The Monitor Class of the device.
Return Type
- ActionResponse|error - Successful operation
rediscover
function rediscover(int deviceId) returns ActionResponse|errorTriggers a new discovery on a specific device.
Parameters
- deviceId int - The ID of the device.
Return Type
- ActionResponse|error - Successful operation
reinitialize
function reinitialize(int deviceId, ReinitializeActionConfiguration payload) returns ActionResponse|errorSends a 'Reinitialize KM' command.
Parameters
- deviceId int - The ID of the device.
- payload ReinitializeActionConfiguration - The request body as a JSON payload.
Return Type
- ActionResponse|error - Successful operation
remove
function remove(int deviceId, string monitorClass, string monitorSid) returns ActionResponse|errorRemoves a specific instance from the monitoring environment.
Parameters
- deviceId int - The ID of the device.
- monitorClass string - The Monitor Class of the device.
- monitorSid string - The Monitor SID of the device.
Return Type
- ActionResponse|error - Successful operation
reset
function reset(int deviceId, string monitorClass, string monitorSid) returns ActionResponse|errorResets the Error Count parameter.
Parameters
- deviceId int - The ID of the device.
- monitorClass string - The Monitor Class of the device.
- monitorSid string - The Monitor SID of the device.
Return Type
- ActionResponse|error - Successful operation
getApplications
function getApplications(string page, int 'limit, string direction, string sort) returns ResultPage|errorGets summarized information about all monitored applications.
Parameters
- page string (default "0") - The page number to retrieve (first page is 0).
- 'limit int (default 100) - The maximum number of entries per page.
- direction string (default "asc") - The sorting order (case insensitive).
- sort string (default "name") - The column to sort by (case insensitive).
Return Type
- ResultPage|error - Successful operation
getOneApplication
function getOneApplication(string applicationId) returns ApplicationSummary|errorGets detailed information for a specific application.
Parameters
- applicationId string - The ID of the application.
Return Type
- ApplicationSummary|error - Successful operation
getDeviceMonitors
Gets the Monitors for a specific device.
Parameters
- deviceId int - The ID of the device.
getDevices
function getDevices(string page, int 'limit, string direction, string sort, string? groupId, string? applicationId, string? serviceId) returns ResultPage|errorGets summarized information about all monitored devices.
Parameters
- page string (default "0") - The page number to retrieve (first page is 0).
- 'limit int (default 100) - The maximum number of entries per page.
- direction string (default "asc") - The sorting order (case insensitive).
- sort string (default "name") - The column to sort by (case insensitive).
- groupId string? (default ()) - The ID of the group.
- applicationId string? (default ()) - The ID of the application.
- serviceId string? (default ()) - The ID of the service.
Return Type
- ResultPage|error - Successful operation
getDevicesSummary
function getDevicesSummary() returns GlobalSummary|errorGets overall information for all devices.
Return Type
- GlobalSummary|error - Successful operation
getDevice
function getDevice(int deviceId) returns DeviceSummary|errorGets detailed information about a specific device.
Parameters
- deviceId int - The ID of the device.
Return Type
- DeviceSummary|error - Successful operation
getDeviceAgent
function getDeviceAgent(int deviceId) returns DeviceAgent|errorGets detailed information about an Agent.
Parameters
- deviceId int - The ID of the device.
Return Type
- DeviceAgent|error - Successful operation
getAgentDevices
function getAgentDevices(int deviceId) returns ResultPage|errorGets a list of all the devices monitored by an Agent.
Parameters
- deviceId int - The ID of the device.
Return Type
- ResultPage|error - Successful operation
getDeviceParameterHistory
function getDeviceParameterHistory(int deviceId, string parameterName, string monitorType, int? 'from, int? to, string? monitorSid) returns ResultPage|errorGets data history for a parameter of a specific device over a given period.
Parameters
- deviceId int - The ID of the device.
- parameterName string - The name of the parameter.
- monitorType string - The unique name of the Monitor type.
- 'from int? (default ()) - Beginning of the period (Epoch time, in seconds).
- to int? (default ()) - End of the period (Epoch time, in seconds).
- monitorSid string? (default ()) - The Monitor SID (to filter the list of Monitors).
Return Type
- ResultPage|error - Successful operation
getDeviceEnergyUsage
function getDeviceEnergyUsage(int deviceId, string rollPeriod, string basis) returns ResultPage|errorGets the energy usage for a specific device and a given period.
Parameters
- deviceId int - The ID of the device.
- rollPeriod string (default "ONE_DAY") - The period for which you wish to retrieve energy usage data.
- basis string (default "HOURLY") - Subdivision of the period for which you wish to retrieve energy usage data.
Return Type
- ResultPage|error - Successful operation
getGroups
Gets all group summaries.
Parameters
- page string (default "0") - The page number to retrieve (first page is 0).
- 'limit int (default 100) - The maximum number of entries per page.
- direction string (default "asc") - The sorting order (case insensitive).
- sort string (default "name") - The column to sort by (case insensitive).
Return Type
- ResultPage|error - Successful operation
getOneGroup
function getOneGroup(string groupId) returns GroupSummary|errorGets detailed information about a specific group.
Parameters
- groupId string - The ID of the group.
Return Type
- GroupSummary|error - Successful operation
updateEnergyCost
function updateEnergyCost(string groupId, GroupConfiguration payload) returns GlobalSummary|errorUpdates the values of the energy footprint parameter for a specific group.
Parameters
- groupId string - The ID of the group.
- payload GroupConfiguration - The values you wish to assign.
Return Type
- GlobalSummary|error - Successful operation
getHeatingMarginCoverage
function getHeatingMarginCoverage(boolean covered, string page, int 'limit, string direction, string sort, string? groupId, string? applicationId, string? serviceId) returns ResultPage|errorGets the heating margin values for each monitored device, when available.
Parameters
- covered boolean (default true) - If set to <em>true</em>, only gets devices whose heating margin information is available.<br>Otherwise, gets any other devices.
- page string (default "0") - The page number to retrieve (first page is 0).
- 'limit int (default 100) - The maximum number of entries per page.
- direction string (default "asc") - The sorting order (case insensitive).
- sort string (default "name") - The column to sort by (case insensitive).
- groupId string? (default ()) - The ID of the group.
- applicationId string? (default ()) - The ID of the application.
- serviceId string? (default ()) - The ID of the service.
Return Type
- ResultPage|error - Successful operation
getHistory
function getHistory(string? groupId, string? applicationId, string? serviceId, int? 'from, int? to) returns ResultPage|errorGets historical data for a specific group, application or service.
Parameters
- groupId string? (default ()) - The ID of the group.
- applicationId string? (default ()) - The ID of the application.
- serviceId string? (default ()) - The ID of the service.
- 'from int? (default ()) - Beginning of the period (Epoch time, in seconds).
- to int? (default ()) - End of the period (Epoch time, in seconds).
Return Type
- ResultPage|error - Successful operation
searchDevices
function searchDevices(string searchTerms, string? groupId, string? applicationId, string? serviceId, string page, int 'limit) returns ResultPage|errorSearches devices by name, model, manufacturer or serial number.
Parameters
- searchTerms string - Space-separated search criteria.
- groupId string? (default ()) - The ID of the group.
- applicationId string? (default ()) - The ID of the application.
- serviceId string? (default ()) - The ID of the service.
- page string (default "0") - The page number to retrieve (first page is 0).
- 'limit int (default 100) - The maximum number of entries per page.
Return Type
- ResultPage|error - Successful operation
getServices
function getServices(string page, int 'limit, string direction, string sort) returns ResultPage|errorGets summarized information about all monitored services.
Parameters
- page string (default "0") - The page number to retrieve (first page is 0).
- 'limit int (default 100) - The maximum number of entries per page.
- direction string (default "asc") - The sorting order (case insensitive).
- sort string (default "name") - The column to sort by (case insensitive).
Return Type
- ResultPage|error - Successful operation
getOneService
function getOneService(string serviceId) returns ServiceSummary|errorGets detailed information about a specific service.
Parameters
- serviceId string - The ID of the service.
Return Type
- ServiceSummary|error - Successful operation
Records
bmc.truesightpresentationserver: ActionResponse
The object encapsulating the output of an operation affecting the PATROL Agent.
Fields
- pslOutput? string - The output of the underlying PSL operation.
bmc.truesightpresentationserver: ApiKeysConfig
Provides API key configurations needed when communicating with a remote HTTP endpoint.
Fields
- authorization string - Represents API Key
Authorization
bmc.truesightpresentationserver: ApplicationSummary
Fields
- id? string - The ID of the application.
- name? string - The name of the application.
- deviceSummaries? DeviceSummary[] - The list of devices attached to the application.<br><u>Note</u>: when using the <b>Applications</b> service, this list is always empty. It is populated only when using the <b>Application Details</b> service.
- totalPowerConsumption? decimal - The total power consumption of the devices attached to the application.
- totalPowerConsumptionUnit? string - The unit in which the total power consumption of the devices attached to the application is being expressed.
- heatingMargin? decimal - The lowest heating margin among the heating margins of the devices attached to the application.<br><u>Note</u>:This field will only be present if a value could be found.
- heatingMarginUnit? string - The unit in which the heating margin of the application is being expressed.
- heatingMarginDeviceName? string - The name of the device having the lowest heating margin.<br><u>Note</u>:This field will only be present if a value could be found.
- heatingMarginDeviceUrl? string - The link to the details of the device having the lowest heating margin.<br><u>Note</u>:This field will only be present if a value could be found.
- heatingMarginCoverage? decimal - The percentage of devices attached to the application, whose heating margin could be found.<br><u>Note</u>:This field will only be present if a value could be found.
- oneDayEnergyConsumption? decimal - The quantity of energy consumed by the devices attached to the application during one day.
- oneDayCost? decimal - The daily cost of the energy consumed by the devices attached to the application.<br><u>Note</u>:This field will only be present if a value could be computed.
- oneDayEmittedCo2? decimal - The quantity of CO<sub>2</sub> emitted by the devices attached to the application during one day.<br><u>Note</u>:This field will only be present if a value could be computed.
- oneDayConfidence? decimal - The confidence score (percentage) for the daily energy consumption, energy cost and CO<sub>2</sub> emission values.<br>The lower the confidence score, the more extrapolated the values are.
- oneMonthEnergyConsumption? decimal - The quantity of energy consumed by the devices attached to the application during one month.
- oneMonthCost? decimal - The monthly cost of the energy consumed by the devices attached to the application.<br><u>Note</u>:This field will only be present if a value could be computed.
- oneMonthEmittedCo2? decimal - The quantity of CO<sub>2</sub> emitted by the devices attached to the application during one month.<br><u>Note</u>:This field will only be present if a value could be computed.
- oneMonthConfidence? decimal - The confidence score (percentage) for the monthly energy consumption, energy cost and CO<sub>2</sub> emission values.<br>The lower the confidence score, the more extrapolated the values are.
- oneYearEnergyConsumption? decimal - The quantity of energy consumed by the devices attached to the application during one year.
- oneYearCost? decimal - The yearly cost of the energy consumed by the devices attached to the application.<br><u>Note</u>:This field will only be present if a value could be computed.
- oneYearEmittedCo2? decimal - The quantity of CO<sub>2</sub> emitted by the devices attached to the application in one year.<br><u>Note</u>:This field will only be present if a value could be computed.
- oneYearConfidence? decimal - The confidence score (percentage) for the yearly energy consumption, energy cost and CO<sub>2</sub> emission values.<br>The lower the confidence score, the more extrapolated the values are.
- updateTimestamp? int - The data collection time (as an Epoch time, in seconds).
- url? string - The link to the application details.
- numberOfDevices? int - The number of devices attached to the application.
- energyConsumptionUnit? string - The unit in which all energy consumption values are being expressed.
- costUnit? string - The currency in which all energy cost values are being expressed.
- emittedCo2Unit? string - The unit in which all CO<sub>2</sub> emission values are being expressed.
- historyParentIdKey? string - The name of the key used to identify the application in the history table.
bmc.truesightpresentationserver: ClientHttp1Settings
Provides settings related to HTTP/1.x protocol.
Fields
- keepAlive KeepAlive(default http:KEEPALIVE_AUTO) - Specifies whether to reuse a connection for multiple requests
- chunking Chunking(default http:CHUNKING_AUTO) - The chunking behaviour of the request
- proxy? ProxyConfig - Proxy server related options
bmc.truesightpresentationserver: ConnectionConfig
Provides a set of configurations for controlling the behaviours when communicating with a remote HTTP endpoint.
Fields
- httpVersion HttpVersion(default http:HTTP_2_0) - The HTTP version understood by the client
- http1Settings? ClientHttp1Settings - Configurations related to HTTP/1.x protocol
- http2Settings? ClientHttp2Settings - Configurations related to HTTP/2 protocol
- timeout decimal(default 60) - The maximum time to wait (in seconds) for a response before closing the connection
- forwarded string(default "disable") - The choice of setting
forwarded/x-forwardedheader
- poolConfig? PoolConfiguration - Configurations associated with request pooling
- cache? CacheConfig - HTTP caching related configurations
- compression Compression(default http:COMPRESSION_AUTO) - Specifies the way of handling compression (
accept-encoding) header
- circuitBreaker? CircuitBreakerConfig - Configurations associated with the behaviour of the Circuit Breaker
- retryConfig? RetryConfig - Configurations associated with retrying
- responseLimits? ResponseLimitConfigs - Configurations associated with inbound response size limits
- secureSocket? ClientSecureSocket - SSL/TLS-related options
- proxy? ProxyConfig - Proxy server related options
- validation boolean(default true) - Enables the inbound payload validation functionality which provided by the constraint package. Enabled by default
bmc.truesightpresentationserver: DeviceAgent
Contains all information regarding a specific PATROL Agent.
Fields
- os? string - The operating system the PATROL Agent is running on.
- name? string - The FQDN of the PATROL Agent.
- 'version? string - The version of the PATROL Agent.
- port? string - The port the PATROL Agent is running on.
- id? string - The ID of the PATROL Agent.
- connectionStatus? string - The status of the PATROL Agent's connection.
- url? string - The link to the 'Monitors' tab of the PATROL Agent.
bmc.truesightpresentationserver: DeviceSummary
Fields
- id? int - The ID of the device.
- name? string - The ID of the device.
- sid? string - The SID of the device.
- serverId? int - The ID of the server the device is attached to.
- serverName? string - The name of the server the device is attached to.
- agentId? int - The ID of the PATROL Agent the device is attached to.
- agentName? string - The name of the PATROL Agent the device is attached to.
- powerConsumption? decimal - The power consumption of the device.
- powerConsumptionUnit? string - The unit in which the power consumption of the device is being expressed.
- heatingMargin? decimal - The heating margin of the device.<br><u>Note</u>:This field will only be present if a value could be found.
- heatingMarginUnit? string - The unit in which the heating margin of the device is being expressed.<br><u>Note</u>:This field will only be present if a value could be found.
- collectTime? string - The collection time of the heating margin (as an Epoch time, in seconds).<br><u>Note</u>:This field will only be present if a value could be found.
- deviceUrl? string - The link to the device details.
- updateTimestamp? int - The data collection time (as an Epoch time, in seconds).
- ambientTemperature? decimal - The ambient temperature of the device.
- 'type? string -
- deviceTSMOKey? string - The TSMOKey of the device.
- productVersion? string - The Hardware Sentry KM version of the device's Monitor.<br><u>Note</u>:This field will only be present if a value could be found.
bmc.truesightpresentationserver: ErrorResponse
Fields
- message? string - The error message.
- date? string - The timestamp of the error.
- code? string - The error's business identifier.
bmc.truesightpresentationserver: GlobalSummary
Fields
- id? string - The ID of the global summary (this ID will always be "global").
- totalPowerConsumption? decimal - The total power consumption of all the devices.
- heatingMargin? decimal - The lowest heating margin among the heating margins of all the devices.<br><u>Note</u>:This field will only be present if a value could be found.
- heatingMarginCoverage? decimal - The percentage of devices whose heating margin could be found.<br><u>Note</u>:This field will only be present if a value could be found.
- heatingMarginDeviceUrl? string - The link to the details of the device having the lowest heating margin.<br><u>Note</u>:This field will only be present if a value could be found.
- heatingMarginDeviceName? string - The name of the device having the lowest heating margin.<br><u>Note</u>:This field will only be present if a value could be found.
- energyCost? decimal - The electricity rate for all devices. This value can be updated by users with sufficient permissions.
- co2Emission? decimal - The CO<sub>2</sub> emissions for all devices. This value can be updated by users with sufficient permissions.
- groupNameFilter? string - Regular expression used to filter the groups for which the power consumption will be reported.
- updateTimestamp? int - The data collection time (as an Epoch time, in seconds).
- totalPowerConsumptionUnit? string - The unit in which the total power consumption is being expressed.
- heatingMarginUnit? string - The unit in which the heating margin is being expressed.
- energyCostUnit? string - The unit in which the electricity rate is being expressed.
- co2EmissionUnit? string - The unit in which the CO<sub>2</sub> emission is being expressed.
- editable? boolean - If <em>true</em>, indicates that you do not have sufficient rights to update the global settings. However, you may still have sufficient rights to update a specific group's setting.
bmc.truesightpresentationserver: GroupConfiguration
The deserialized form of the Energy Footprint Update service's request payload.
Fields
- energyCost? decimal - Updates the electricity rate (unit: $/kWh).
- co2Emission? decimal - Updates the CO<sub>2</sub> emission (unit: kg/kWh).
- groupNameFilter? string - Updates the regular expression used to filter the groups for which the power consumption should be reported.
bmc.truesightpresentationserver: GroupSummary
Fields
- id? string - The ID of the group.
- name? string - The name of the group.
- serverId? int - The ID of the server the group is attached to.
- deviceSummaries? DeviceSummary[] -
- totalPowerConsumption? decimal - The total power consumption of the devices attached to the group.
- totalPowerConsumptionUnit? string - The unit in which the total power consumption of the devices attached to the group is being expressed.
- heatingMargin? decimal - The lowest heating margin among the heating margins of the devices attached to the group.<br><u>Note</u>:This field will only be present if a value could be found.
- heatingMarginUnit? string - The unit in which the heating margin of the group is being expressed.
- heatingMarginDeviceName? string - The name of the device having the lowest heating margin.<br><u>Note</u>:This field will only be present if a value could be found.
- heatingMarginDeviceUrl? string - The link to the details of the device having the lowest heating margin.<br><u>Note</u>:This field will only be present if a value could be found.
- heatingMarginCoverage? decimal - The percentage of devices attached to the group, whose heating margin could be found.<br><u>Note</u>:This field will only be present if a value could be found.
- energyCost? decimal - The electricity rate for all devices attached to the group. This value can be updated by users with sufficient permissions.
- co2Emission? decimal - The CO<sub>2</sub> emissions for all devices attached to the group. This value can be updated by users with sufficient permissions.
- oneDayEnergyConsumption? decimal - The quantity of energy consumed by the devices attached to the group during one day.
- oneDayCost? decimal - The daily cost of the energy consumed by the devices attached to the group.<br><u>Note</u>:This field will only be present if a value could be computed.
- oneDayEmittedCo2? decimal - The quantity of CO<sub>2</sub> emitted by the devices attached to the group during one day.<br><u>Note</u>:This field will only be present if a value could be computed.
- oneDayConfidence? decimal - The confidence score (percentage) for the daily energy consumption, energy cost and CO<sub>2</sub> emission values.<br>The lower the confidence score, the more extrapolated the values are.
- oneMonthEnergyConsumption? decimal - The quantity of energy consumed by the devices attached to the group during one month.
- oneMonthCost? decimal - The monthly cost of the energy consumed by the devices attached to the group.<br><u>Note</u>:This field will only be present if a value could be computed.
- oneMonthEmittedCo2? decimal - The quantity of CO<sub>2</sub> emitted by the devices attached to the group during one month.<br><u>Note</u>:This field will only be present if a value could be computed.
- oneMonthConfidence? decimal - The confidence score (percentage) for the monthly energy consumption, energy cost and CO<sub>2</sub> emission values.<br>The lower the confidence score, the more extrapolated the values are.
- oneYearEnergyConsumption? decimal - The quantity of energy consumed by the devices attached to the group during one year.
- oneYearCost? decimal - The yearly cost of the energy consumed by the devices attached to the group.<br><u>Note</u>:This field will only be present if a value could be computed.
- oneYearEmittedCo2? decimal - The quantity of CO<sub>2</sub> emitted by the devices attached to the group in one year.<br><u>Note</u>:This field will only be present if a value could be computed.
- oneYearConfidence? decimal - The confidence score (percentage) for the yearly energy consumption, energy cost and CO<sub>2</sub> emission values.<br>The lower the confidence score, the more extrapolated the values are.
- updateTimestamp? int - The data collection time (as an Epoch time, in seconds).
- url? string - The link to the group details.
- numberOfDevices? int - The number of devices attached to the group.
- energyCostUnit? string - The unit in which th euser-defined electricity rate value is being expressed.
- ambientTemperature? decimal - The average ambient temperature based on the ambient temperatures of the devices attached to the group.
- ambientTemperatureUnit? string - The unit in which the ambient temperature value is being expressed.
- co2EmissionUnit? string - The unit in which the user-defined CO<sub>2</sub> emission value is being expressed.
- energyConsumptionUnit? string - The unit in which all energy consumption values are being expressed.
- costUnit? string - The currency in which all energy cost values are being expressed.
- emittedCo2Unit? string - The unit in which all emitted CO<sub>2</sub> quantities are being expressed.
- historyParentIdKey? string -
- editable? boolean - The name of the key used to identify the group in the history table.
bmc.truesightpresentationserver: ProxyConfig
Proxy server configurations to be used with the HTTP client endpoint.
Fields
- host string(default "") - Host name of the proxy server
- port int(default 0) - Proxy server port
- userName string(default "") - Proxy server username
- password string(default "") - Proxy server password
bmc.truesightpresentationserver: ReinitializeActionConfiguration
The deserialized form of the Reinitialize service's request payload.
Fields
- resetDiscoveryAndPollingIntervals? int - When set to <em>1</em>, removes all user-defined frequencies for discovery and polling processes to their default values (respectively 1 hour and 2 minutes).
- resetAlertAfterNTimes? int - When set to <em>1</em>, resets the number of times thresholds can be breached before triggering an alert to their default values (1 time) for numeric, discrete, connector status and present parameters.
- resetAlertActions? int - When set to <em>1</em>, removes all manually set Alert Actions and reverts to basic default actions i.e. trigger a PATROL event and annotate a parameter graph.
- resetOtherAlertSettings? int - When set to <em>1</em>, reverts any manually performed configuration changes to the default Hardware Sentry values.
- resetDebugMode? int - When set to <em>1</em>, deactivates the debug mode when it was manually enabled.
- resetRemovedPausedObjectList? int - When set to <em>1</em>, reactivates the monitoring of all paused or removed objects.
- resetReportSettings? int - When set to <em>1</em>, clears the report schedule.
- resetJavaSettings? int - When set to <em>1</em>, removes the custom Java settings (path and credentials). The KM will try to automatically find a suitable JRE.
- resetThresholds? int - When set to <em>1</em>, resets all thresholds.
bmc.truesightpresentationserver: ResultPage
Encapsulates a list of results.
Fields
- items? record {}[] - The list of currently accessible results.
- total? int - The total number of accessible results, including the results not listed in <em>items</em>.
- restrictedRights? boolean - If <em>true</em>, indicates that you are denied access to part of, or all the results.
bmc.truesightpresentationserver: ServiceSummary
Fields
- id? string - The ID of the service.
- name? string - The name of the service.
- providerId? string - The ID of the server providing the service.
- deviceSummaries? DeviceSummary[] - The list of devices attached to the service.<br><u>Note</u>: when using the <b>Services</b> service, this list is always empty. It is populated only when using the <b>Service Details</b> service.
- totalPowerConsumption? decimal - The total power consumption of the devices attached to the service.
- totalPowerConsumptionUnit? string - The unit in which the total power consumption of the devices attached to the service is being expressed.
- heatingMargin? decimal - The lowest heating margin among the heating margins of the devices attached to the service.<br><u>Note</u>:This field will only be present if a value could be found.
- heatingMarginUnit? string - The unit in which the heating margin of the service is being expressed.
- heatingMarginDeviceName? string - The name of the device having the lowest heating margin.<br><u>Note</u>:This field will only be present if a value could be found.
- heatingMarginDeviceUrl? string - The link to the details of the device having the lowest heating margin.<br><u>Note</u>:This field will only be present if a value could be found.
- heatingMarginCoverage? decimal - The percentage of devices attached to the service, whose heating margin could be found.<br><u>Note</u>:This field will only be present if a value could be found.
- oneDayEnergyConsumption? decimal - The quantity of energy consumed by the devices attached to the service during one day.
- oneDayCost? decimal - The daily cost of the energy consumed by the devices attached to the service.<br><u>Note</u>:This field will only be present if a value could be computed.
- oneDayEmittedCo2? decimal - The quantity of CO<sub>2</sub> emitted by the devices attached to the service during one day.<br><u>Note</u>:This field will only be present if a value could be computed.
- oneDayConfidence? decimal - The confidence score (percentage) for the daily energy consumption, energy cost and CO<sub>2</sub> emission values.<br>The lower the confidence score, the more extrapolated the values are.
- oneMonthEnergyConsumption? decimal - The quantity of energy consumed by the devices attached to the service during one month.
- oneMonthCost? decimal - The monthly cost of the energy consumed by the devices attached to the service.<br><u>Note</u>:This field will only be present if a value could be computed.
- oneMonthEmittedCo2? decimal - The quantity of CO<sub>2</sub> emitted by the devices attached to the service during one month.<br><u>Note</u>:This field will only be present if a value could be computed.
- oneMonthConfidence? decimal - The confidence score (percentage) for the monthly energy consumption, energy cost and CO<sub>2</sub> emission values.<br>The lower the confidence score, the more extrapolated the values are.
- oneYearEnergyConsumption? decimal - The quantity of energy consumed by the devices attached to the service during one year.
- oneYearCost? decimal - The yearly cost of the energy consumed by the devices attached to the service.<br><u>Note</u>:This field will only be present if a value could be computed.
- oneYearEmittedCo2? decimal - The quantity of CO<sub>2</sub> emitted by the devices attached to the service in one year.<br><u>Note</u>:This field will only be present if a value could be computed.
- oneYearConfidence? decimal - The confidence score (percentage) for the yearly energy consumption, energy cost and CO<sub>2</sub> emission values.<br>The lower the confidence score, the more extrapolated the values are.
- updateTimestamp? int - The data collection time (as an Epoch time, in seconds).
- url? string - The link to the service details.
- numberOfDevices? int - The number of devices attached to the service.
- energyConsumptionUnit? string - The unit in which all energy consumption values are being expressed.
- costUnit? string - The currency in which all energy cost values are being expressed.
- emittedCo2Unit? string - The unit in which all CO<sub>2</sub> emission values are being expressed.
- historyParentIdKey? string - The name of the key used to identify the service in the history table.
Import
import ballerinax/bmc.truesightpresentationserver;Metadata
Released date: about 9 hours ago
Version: 1.5.2
License: Apache-2.0
Compatibility
Platform: any
Ballerina version: 2201.8.0
GraalVM compatible: Yes
Pull count
Total: 27
Current verison: 0
Weekly downloads
Keywords
Type/Connector
Vendor/BMC
Area/Cloud & Infrastructure
IT Operations/Server Monitoring
Cost/Freemium
Contributors
Dependencies